Errors and warnings

Background

The Engine generates error and warning messages based on input data, results from power system software or through unexpected behaviour. Below is a list of Engine errors and warnings which have additional information on what is causing the error or warning and how to resolve it.

As always, if you need help with an error or warning, please reach out to gridmo support.

Errors

  • Error 100 | [Various software] | Cannot find object
  • Error 110 | [Various software] | SIMPLEFAULT negative impedance
  • Error 114 | [Various software] | METERBUS= is ambiguous for a three winding transformer
  • Error 118 | [Various software] | External grid control data is invalid
  • Error 119 | [Various software] | External grid control data not in ascending order
  • Error 123 | [Various software] | Could not find a matching version of the software to launch
  • Error 125 | [Various software] | Cannot copy file
  • Error 128 | [Various software] | Invalid task type
  • Error 129 | [Various software] | Invalid internode variable definition
  • Error 130 | [Various software] | Could not find internode variable
  • Error 135 | [Various software] | Invalid internode data
  • Error 140 | [Various software] | Stopping stalled process
  • Error 142 | [Table] | Internode variables not supported in table column names
  • Error 143 | [Various software] | SIMPLEFAULT FZ=x% argument is invalid
  • Error 144 | [Various software] | TOVTEST QCAP=CALC TARGET= argument is invalid
  • Error 145 | [Various software] | External grid control data invalid internode import
  • Error 147 | [Various software] | Task will be retried
  • Error 150 | [PSCAD] | Negative SCR or X/R value detected
  • Error 154 | [Various software] | Could not process command
  • Error 159 | [Various software] | Invalid tap ratio specified
  • Error 160 | [PSS®E] | Invalid response from PSS®E
  • Error 163 | [PSS®E] | No swing bus present
  • Error 166 | [PSS®E] | Could not find any PSS®E versions
  • Error 167 | [PSS®E] | Could not find matching dynamic model
  • Error 259 | [PSCAD™] | Build error
  • Warnings

  • Warning 101 | [PSS®E] | Thévenin source impedance abnormally high
  • Warning 102 | [PSCAD™] | Plot step is abnormally large
  • Warning 103 | [PSS®E] | Case file has non-standard system base
  • Warning 104 | [PSCAD™] | PSCAD™ output is ambiguous
  • Warning 105 | [Various software] | Object out of service
  • Warning 106 | [Various software] | Turning off reference bus
  • Warning 107 | [PSS®E] | Thévenin source impedance abnormally low
  • Warning 108 | [PSS®E] | Line impedance abnormally low
  • Warning 109 | [PSS®E] | SMIB Distance Factor with low source impedance
  • Warning 111 | [PSS®E] | SIMPLEFAULT applied at infinite bus
  • Warning 112 | [PSS®E] | SMIB fault not on Thévenin source branch
  • Warning 113 | [PSCAD™] | Cannot find output TITLE=
  • Warning 120 | [PSS®E] | Two-winding transformer with both taps off-nominal
  • Warning 121 | [Various software] | SCR= or XR= set on a branch that is not connected to a swing or reference bus
  • Warning 122 | [PSS®E] | Islanded assets detected during SOLVE
  • Warning 124 | [Various software] | Multiple assets matched definition
  • Warning 126 | [Various software] | Program blocking temp file cleanup
  • Warning 131 | [Various software] | Multiple internode values found where one expected
  • Warning 146 | [Various software] | External grid control mode not selected
  • Warning 149 | [Plot] | Divide by zero detected
  • Warning 153 | [Various software] | TOVTEST QCAP argument is too low
  • Warning 157 | [Various software] | Ambiguous power factor command
  • Warning 162 | [PSS®E] | Multiple swing buses detected
  • Warning 168 | [PSCAD™] | Cannot find smiby block