Error 268 | [DSATools™ TSAT] | Operation requires linked static simulation model


Relevant software:

DSATools™
TSAT
PSAT
PSS®E


Emitted message:

This operation requires TSAT to load a model from a linked node. Please ensure the TSAT node uses a model from a linked node and that there is only one static simulation node linked.

Description:

Some DSATools™ TSAT behaviour requires TSAT to load power flow and bus context from a linked upstream static simulation (a PSAT node or PSS®E Static Simulation node), rather than relying only on what is configured locally in the TSAT node.

Potential fixes:

  1. On the TSAT node, enable Use model from linked PSAT or PSS®E Static Node (or equivalent) so power flow is taken from the connected static simulation, as described in the TSAT reference.

  2. Within your flow, link TSAT to one PSAT or PSS®E Static Simulation node that runs before TSAT and carries the model you want TSAT to use.