Error 136 | [Various software] | Internode data Engine version mismatch
Relevant software:
PSS®E
PowerFactory
PSCAD™
Emitted message:
The Engine version of the internode data does not match the Engine version of the current Engine
Description:
This error indicates that the gridmo Engine is trying to load Internode data that was created by a different Engine version. Internode data can only be shared between Engines which are the same version.
This is likely either:
- An Engine in an Engine group is a different version to this Engine. Data cannot be shared between Engines which are not the same version.
- The Engine was updated during a simulation.
danger
This error will cause the task to fail, because the Internode data from the linked Node cannot be loaded.
Possible impact:
- The task will fail and will not produce outputs that depend on the linked Node's Internode data.
Potential fixes:
- Use the same Engine version across the Engine group: Update every Engine in the Engine group so they are all running the same version, then relaunch the simulation.
- Relaunch the simulation after an Engine update: If the Engine was updated while a simulation was running, cancel the simulation and start it again so all Internode data is written by the current Engine version.