Skip to main content

Error 136 | [Various software] | Internode data Engine version mismatch


Relevant software:

PSS®E
PowerFactory
PSCAD™


Emitted message:

The Engine version of the internode data does not match the Engine version of the current Engine

Description:​

This error indicates that the gridmo Engine is trying to load Internode data that was created by a different Engine version. Internode data can only be shared between Engines which are the same version.

This is likely either:

  • An Engine in an Engine group is a different version to this Engine. Data cannot be shared between Engines which are not the same version.
  • The Engine was updated during a simulation.
danger

This error will cause the task to fail, because the Internode data from the linked Node cannot be loaded.

Possible impact:​

  • The task will fail and will not produce outputs that depend on the linked Node's Internode data.

Potential fixes:​

  • Use the same Engine version across the Engine group: Update every Engine in the Engine group so they are all running the same version, then relaunch the simulation.
  • Relaunch the simulation after an Engine update: If the Engine was updated while a simulation was running, cancel the simulation and start it again so all Internode data is written by the current Engine version.